01299 253528 [email protected] Mon - Thur: 8:30 - 17:00 | Fri: 08:30 - 16:00
Enquire
01299 253528 [email protected] Mon - Thur: 8:30 - 17:00 | Fri: 08:30 - 16:00

WalkAngel roof walkways create defined, anti-slip routes for safe access at height, protecting operatives and the roof build-up. Freestanding, roof-fixed or seam-clamped options suit most roof types and integrate with guardrails and ladders.

Roof Walkway Systems

WalkAngel establishes permanent roof walkways that transform safe access whilst protecting operatives and roof infrastructure. This engineered system utilises recycled uPVC boards on extruded I-beam assemblies, delivering robust load distribution that preserves roof integrity and maintains warranties.

Three installation methods accommodate diverse constructions: freestanding weighted for flat roofs, top-fix to trapezoidal decks using SFS IRIUS self-sealing screws, and clamp-fix to standing seams with S-5® mini clamps. CE-marked to EN 516:2006 (Class 1-C) with SATRA testing, WalkAngel provides documented compliance.

Available in 1.5m and 3m lengths with levelled and step variants for specific roof angles, adapting to pitched and barrel configurations whilst maintaining anti-slip performance.

Why Choose WalkAngel

  • Defined Anti-Slip Access Routes
    WalkAngel creates designated walkways with immediate anti-slip protection, eliminating slip/trip hazards whilst directing foot traffic away from fragile or weathered roof areas. The uPVC board-and-I-beam assembly distributes loading effectively to protect roof build-up and preserve warranties, functioning as a dedicated walkway system rather than fall-arrest attachment point.
  • Adaptive Installation Technology
    Three installation modes accommodate most roof constructions: freestanding weighted for flat roofs (zero penetrations), top-fix to trapezoidal crowns using SFS IRIUS self-sealing screws with foam pads, and clamp-fix to standing seams via S-5® mini clamps at 600-1200mm centres, with panels supplied in 1.5m and 3m lengths plus custom-angled variants for complex geometries.
  • Certified Compliance Framework
    CE-marked to EN 516:2006 (Class 1-C) with independent SATRA testing, supported by comprehensive technical guidance covering layout specifications, fixing patterns, and component selection. Installation by competent personnel following site plans ensures compliance, whilst ongoing maintenance requires only periodic inspection and cleaning, with typical 3m panels weighing 32-34kg for safe handling protocols.

Versatile Roof Walkway System

  • Walkway and Access Systems
  • Aluminium, 316 Stainless Steel and recycled uPVC
  • Extensive Testing in Excess of Standards Requirements
  • Factory Assembly for Reduced Install Time and Increased Productivity
  • Minimal Packaging for Reduced Waste

Roofing Types

  • Polymeric Single-Ply Membranes
  • Bituminous Membranes
  • Trapezoidal Sheeting
  • Standing Seam Sheeting
  • Composite/Built-Up Systems
  • Concrete/Masonry Roofs.

Product Certifications

Technical Specifications & Features

WalkAngel integrates precision-extruded uPVC construction with engineered I-beam assemblies to deliver certified roof walkway performance across diverse substrates. Our system achieves EN 516:2006 Class 1-C compliance through independent SATRA testing protocols, whilst maintaining load distribution efficiency and anti-slip characteristics. Every component undergoes rigorous structural analysis for deflection limits, material durability assessment, and fixing compatibility verification to ensure predictable walkway performance under operational loading conditions.

  • Recycled uPVC Board Construction
    High-grade recycled uPVC boards mounted on extruded uPVC I-beam assemblies provide superior load distribution across roof substrates, protecting membrane integrity and roof build-up whilst delivering consistent anti-slip surface performance with minimal maintenance requirements.
  • Triple Installation Methodology
    Engineered fixing solutions accommodate diverse roof constructions: freestanding weighted configurations for flat applications (zero penetrations), top-fix installations using SFS IRIUS self-sealing tek screws with foam pads on trapezoidal crowns, and clamp-fix systems with S-5® mini clamps at 600-1200mm centres for standing seam applications.
  • EN 516:2006 Class 1-C Certification
    Independent SATRA testing verification to European walkway standards provides documented slip resistance and load capacity performance, supporting CDM compliance and workplace safety requirements through comprehensive CE marking and technical documentation protocols.
  • Modular Panel Engineering
    Available in 1.5m and 3m panel lengths with levelled and step variants manufactured to specific roof angles, accommodating pitched and barrel roof configurations whilst maintaining structural continuity and anti-slip performance across complex geometries.
  • Load-Optimised Design
    Typical 3m panel mass of 32-34kg enables safe manual handling whilst I-beam construction distributes operational loads effectively, preventing roof damage and maintaining building warranties through calculated load distribution and minimal point loading characteristics.
UPVC Rooftop walkway | Walk Angel

Request a Quote · Book a Roof Survey · Speak to a Technical Specialist

Ready to Create Safe Roof Access Routes?

Transform roof safety with EN 516-certified WalkAngel Walkway Systems. Get project-specific layouts and fixed-price quotes for permanent access solutions that protect operatives whilst preserving roof integrity and building warranties.

  • EN 516:2006 Class 1-C Certified with independent SATRA testing verification
  • Three Installation Methods accommodating all major roof constructions
  • Zero Roof Penetrations available through freestanding weighted options
  • Integrated System Compatibility with guardrails, ladders, and access routes
Make an Enquiry

FAQs

WalkAngel FAQs: Expert Answers to Your Safety Questions

Get instant answers to the most critical questions about WalkAngel Roof Walkways and Anti-Slip Routes. Whether you’re specifying for a new project, evaluating existing systems, or planning maintenance schedules, our comprehensive FAQ section provides the technical insights and regulatory guidance you need.

WalkAngel systems accommodate metal, membrane, tile, and composite roof surfaces. Our modular design adapts to various roof profiles whilst engineered base plates distribute loads safely without compromising roof warranties or structural integrity.

Our systems meet Working at Height Regulations 2005 requirements for safe roof access routes. Anti-slip surfaces achieve SRV 55+ ratings whilst load distribution prevents membrane damage, ensuring compliant pedestrian access.

Minimal maintenance is required. The self-cleaning surface texture and UV-stabilised materials eliminate ongoing upkeep. Periodic visual inspections ensure continued performance without cleaning schedules or surface treatments.

Yes, the lightweight modular components install without roof penetration or structural alterations. Load distribution technology accommodates existing roof specifications whilst single-operative installation minimises site disruption.

UV-stabilised recycled PVC construction delivers 25+ year service life. Materials withstand -40°C to +70°C thermal cycling without dimensional change, maintaining slip resistance and structural performance throughout operational lifespan.

Rapid deployment using lightweight components enables single-operative installation without specialist equipment. Standard walkway routes can typically be completed within hours, reducing project timescales and roof access disruption.

Make an Enquiry Today

Ready to get started? Get in touch to learn more about our fall protection solutions and how we can help you improve safety for workers at height.